SPEC 70859

Southwire Electric Vehicle EVE/EVJE and EV/EVJ Cables

90° or 105°C Dry/60°C Wet. 300, 600/1000 Volts. Class K, Bare Copper Conductors. TPE or EPDM Insulation and TPE or CPE oil, sunlight and flame resistant jacket.

...

Construction:

  1. Conductor:Class K, Flexible stranded bare copper per ASTM B3 and ASTM B174
  2. Insulation:Thermoplastic Elastomer (TPE) with Optional Nylon Covering or Ethylene Propylene Diene Monomer (EPDM)
  3. Filler:Paper or Polypropylene filler as needed
  4. Binder:Paper or Talc as needed
  5. Overall Jacket:Black; Thermoplastic Elastomer (TPE) or Thermoset Chlorinated Polyethylene (CPE)

Applications and Features:

EV Charging Cables, designed for residential or commercial charging applications. Flexible construction, cabled with fillers, with wet rated, oil resistant, crush and impact resistant, low temperature materials. These cables meet Underwriters Laboratories and the Canadian Standard Association requirements as well as the National Electrical Code articles 400 (Flexible Cords & Flexible Cables) and 625 (Electric Vehicle Power Transfer System).

Voltage: 300V EVJE, EVJ; 600V or 1000V EVE or EV.
Temperature Range: -40°C to 105°C Dry, 60°C Wet

Specifications:

  • ASTM B3 Standard Specification for Soft or Annealed Copper Wire
  • ASTM B174 Standard Specification for Bunch-Stranded Copper
  • UL 62 Flexible Cords and Cables
  • RoHS-3 Complies with European Directive 2015/863
  • Sample Print Legend:

    SOUTHWIRE® 3/C XX AWG (X.XXmm2) & 1/C XX AWG (X.XXmm2) EVE E312819 c(UL)us 1000V 105C DRY 60C WET -- EVT(TPE) 1000V 105C DRY 60C WET FT2 WATER RESISTANT -- FOR USE WITH ELECTRIC VEHICLES
    Types EVJE or EVJ, 300V
    Stock CodeCond. Size2/Cond. Plus GrndNo. of StrandsInsulation Average ThicknessInsulation Average ThicknessJacket Average ThicknessJacket Average ThicknessNominal ODNominal ODNominal WeightNominal WeightAmpacity†
    (AWG)(inches)(mm)(inches)(mm)(inches)††(mm)(Lbs/Mft)††(kg/km)††amps
    EVJE14143410.0300.760.0300.760.3749.508813018
    181160.0300.76
    EVJE12123650.0300.760.0451.140.46311.7613319825
    181160.0300.76
    EVJ14143410.0300.760.0300.760.3749.509413918
    181160.0300.76
    EVJ12123650.0300.760.0451.140.46311.7614521625
    181160.0300.76
    Types EVE or EV, 600V or 1000V
    Stock CodeCond. Size2/Cond. Plus GrndNo. of StrandsInsulation Average ThicknessInsulation Average ThicknessJacket Average ThicknessJacket Average ThicknessNominal ODNominal ODNominal WeightNominal WeightAmpacity†
    (AWG)(inches)(mm)(inches)(mm)(inches)††(mm)(Lbs/Mft)††(kg/km)††amps
    EVE14143410.0451.140.0802.030.54913.9415222618
    181160.0300.76
    EVE12123650.0451.140.0802.030.57914.7118427425
    181160.0300.76
    EVE101031040.0451.140.0802.030.61415.623334630
    181160.0300.76
    EVE08831680.0601.520.1253.180.85821.7942463140
    181160.0300.76
    EVE06632660.0601.520.1253.180.92723.5554881655
    181160.0300.76
    EVE04434200.0601.520.1403.561.10628.09774115270
    181160.0300.76
    EVE02236650.0601.520.1403.561.20530.611062158095
    181160.0300.76
    EV14143410.0451.140.0802.030.54913.9417225618
    181160.0300.76
    EV12123650.0451.140.0802.030.57914.7120730825
    181160.0300.76
    EV101031040.0451.140.0802.030.61415.625838330
    181160.0300.76
    EV08831680.0601.520.1253.180.85821.7946969740
    181160.0300.76
    EV06632660.0601.520.1253.180.92723.5560289655
    181160.0300.76
    EV04434200.0601.520.1403.561.10628.09852126870
    181160.0300.76
    EV02236650.0601.520.1403.561.20530.611147170895
    181160.0300.76

    Footnotes

    Additional sizes & Custom Designs are available.
    All dimensions are nominal and subject to normal manufacturing tolerances
    † Ampacities are based on Table 400.5(A)(1) of the NEC, 2020 Edition. Ampacities of insulated conductors based on ambient temperature of 30°C (86°F)
    †† Cable OD's and Weights are subject to change.

    Revision: